Used for rapid identification and typing of microorganisms, including bacteria, fungi, mycobacteria, and anaerobic bacteria.

Performance:

Detection mass range: 0.1-500 kDa; Resolution: ≥5000 FullWidth at Half Maximum(FWHM)

 

• Mass accuracy: Protein mixture: <200 ppm (external calibration), <150 ppm (internal calibration), Sensitivity: 10 amol/uL

• Utilizes a 343nm solid-state laser with over 2 billion shots

• Integrated ion source, no cleaning required; and laser incidence angle <5°

• Dual-pulse delayed extraction technology for improved full mass resolution

• Optical design incorporates high transmission efficiency lens modules, ensuring laser energy attenuation of less than 10%

• Adjustable laser spot diameter of 80-300 pm, providing enhanced processing capability for different sample types

• Integrated data collection and microbial identification software system for simplified and user-friendly operation

•    Durable, Long-Lasting solid-state laser:

Increased lifespan by 40 times compared to others,requiring minimal maintenance; Provides excellent performance, enhancing analysis efficiency.

•    Patented ion source structural design:

Industry-leading minimal angle design;

Eliminates shadowing effects, improving sensitivity and resolution.

•    Dual-pulse delayed extraction technology:

Enhanced resolution across a wide mas sranges;

lmproved resolution across the entire mass ranges.

•    Most reliable microbial database:

Sourced from the national CDC, ensuring authoritative and reliable data;

Widest variety and most comprehensive quantity of databases;

Best suited for microbial identification applications in clinical microbiology.


•    Database:

The database includes over 480 genera, 3,580 species, and over 68,000 microbial spectra; It covers a wide range of fields including clinical, animal, plant, engineering, environmental, and soil; Advanced spectrum classification algorithms and weight matrix algorithms are employed, ensuring more accurate identification; Users are allowed to customize the database according to their specific needs, providing greater convenience and flexibility in usage.


•    Reagent:

• Sample Preparation Reagent:


Bacteria and Yeast Fungi Sample Release Reagents (includes: lysis solution 1 and matrixsolution) Filamentous Fungal Sample Release Reagents (includes: lysis solution 1, lysis solution 2, and matrix solution)


• Matching Target Panels:


96-well separated stainless steel-coated target plate and holder.